The Chroma features a ground continuity check function as well.

Under test, Pass, Fail. If the DUT is shorting, total capacitive load is higher than that of normal conditions.

Chroma Guardian 19052 Hipot Test (AC/DC/IR)

In contrast, when electrical discharge occurs due to poor insulation materials, electrode gaps, surface clearances, 199052. Taking the output voltage 5kVac for example, when the output of Hipot tester is not synchronized, the two DUTs may create a discharge of high voltage difference up to14kV peak-peak and cause the fixture to be damaged and erroneous judgment.

If the connection is open, a capacitance will appear and total capacitive load will be lower than that of normal conditions. When planning for production line or automation, minimized facility and optimized space are often utilized in the plant; therefore, the distance between two DUTs is usually very crhoma. This model consumes W of power and weighs around 15 kg.

It makes the entire capacitance of the product lower than normal value. LCR Meters LCR Meters Meters are used for impedance measurements inductance, capacitance, and resistance to characterize the performance of a variety of electrical components and materials.

  DEFIANCE BIELSKI PARTISANS PDF

Barletta – Multi-Hipot Tester series

This website is not sanctioned or approved by any manufacturer or tradename listed. Medical Systems A QuadTech System provides automated electrical safety testing and may include a combination of an electrical safety analyzer, software, ac source, scanner, custom test leads, PC or more. No hassle return policy. This increases the test reliability and efficiency significantly through application of the contact check during the Hipot test. The Series Hipot Analyzers with VA output power can be used to test and analyze the high power withstand voltage and leakage current for products like motor stators and rotors with larger parasitic capacitance.

The Chroma Hipot Tester series provide 3 models for choice. Dedicated customer service team. This is a phenomenon of poor withstanding. It contains several international patents and is the best tool for electrical regulatory hipot test as not only reliable quality can be obtained, highly efficient test platform can be created.

LCR Meters Meters are used for impedance measurements inductance, capacitance, and resistance to characterize the performance of a variety of electrical components and materials. The change rates of test voltage or leakage current are monitored to detect flashover as its detection is one of the most indispensable test items for electrical safety test. Charge and discharge are required for capacitive components when doing DC withstand voltage test. Start, Stop, Interlock at 11 pin terminal block only ; Output: Testing continually leads to instrument failure due to it suffering the high load current.

When the circuit connection is interrupted, a small capacitance Cc in Figure 6 will be formed on the broken interface that is usually lower than 10pF. Chroma series are the smallest Hipot Testers currently available in the world.

  FLIGHTGEAR MANUALE ITALIANO PDF

To protect users, this model has a GFI ground fault interrupt function as well. Chroma Technical Specifications: If any gap, void or impurity is produced during molding of parts in the manufacturing process, the insulation capability of the product can be affected. All trademarks that appear on this website are the property of their respective owners.

It can cause a carbonized conductive path or damage the product under test.

This model provides 0. C function is used to check whether the connection is open or is a short circuit between the instrument and the DUT equipment under test before the Electrical Safety Test begins.

Corona Discharge Detection CDD can also be chtoma for coil-to-coil or coil-to ground tests to eliminate winding insulation failure due to Corona discharge. With more than 20 years experience cyroma developing the instruments for test and measurement, Chroma creates the multi-channel hipot tester with a brand new architecture.

Hipot Tester AC and DC Hipot, Insulation Resistance – Liberty Test Equipment

Chroma Technical Specifications. Please refer to the application notes for more detail information. Rate the Chroma 1 2 3 4 5 Rated 4.

To communicate with other compatible devices and for remote controlling, the comes equipped with an RS interface. Transformer When a power transformer is used under normal voltage, Corona discharge from the primary side could cause damage to nearby components.